N8 – 20 + 20 Low Voltage reactive power integrated intelligent power capacitor Reactive compensation capacitor
N8 series intelligent capacitor
environment condition
Poster height: ≤ 2500m
Working temperature: – 20 ℃~ + 45 ℃
Storage temperature: – 25 ℃~ + 60 ℃
Rated voltage: 0.4kV
Rated capacity: ≤ 40kvar three phase
≤ 10kvar single item
Protection grade: IP20
Executive standard: gb15576-2008
Weight: about 4.88kg (20 + 20kvar)
Switching element: synchronous switch
Protection function: overvoltage / overtemperature / harmonic overrun
Harmonics: non suppressed harmonics
Compensation mode: split phase compensation / three phase compensation / mixed compensation
-
N7-40 Kvar co compensation anti harmonic intelligent capacitor
N7 series intelligent capacitor
environment condition
Poster height: ≤ 2500m
Working temperature: – 20 ℃~ + 45 ℃
Storage temperature: – 25 ℃~ + 60 ℃
Rated voltage: 0.4kV
Rated capacity: ≤ 40kvar three phase
≤ 10kvar single item
Protection grade: IP20
Executive standard: gb15576-2008
Weight: about 25.68kg (30F)
Switching element: synchronous switch
Protection function: over current / overtemperature / harmonic overrun
Harmonics: with suppressed harmonics
Compensation mode: split phase compensation / three phase compensation
-
NFC-3050/3006 series intelligent reactive power automatic compensation controller
Nfc-3050 / 3060 high voltage controller
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U 59-690v wide range
Working power supply: 85V ~ 265V AC / DC power supply
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor: 12 (model 3050) / 6 (type 3060)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: 0.48kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138 mm
Application orientation: industrial customers
-
JKWV 7 Inch Touch screen control low voltage reactive power automatic compensation controller
Jkwv-32 series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network cable control
Number of control capacitor circuits: 32
Human machine interface: LCD touch screen
Communication: RJ45 network interface
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: 2.18kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Whether backstage is supported: Yes
Opening size: 215 × 152 mm
Application orientation: industrial customers
-
JKWI-12(A/B)-32-S/D RJ45 network interface intelligent compensation controller
Jkwi series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 380VAC, 50Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network interface
Static (a) / dynamic (b)
Number of control capacitor: 12 / 32 (A / b)
Human machine interface: LED
Communication: RJ45 network interface
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: A: 0.74kg B: 0.78kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: building Park
-
JKWH-21 channel compensation control interface reactive power compensation controller
Jkwh series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement / sub supplement / CO supplement + sub supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 21 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants
Weight: A: 1.04kg B: 0.92kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: industrial customers
-
JkwG-32 LCD dot matrix LCD automatic compensation controller
Jkwg-32 series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: II + 2U / 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage, temperature and harmonic
Control scheme: CO supplement / CO supplement + sub supplement
Control output mode: network cable control
Number of control capacitor circuits: 32
Human machine interface: LCD
Communication: RJ45 network interface / RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: 0.88kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Whether backstage is supported: Yes
Opening size: 138 × 138 mm
-
JKWF-12(A/B) series intelligent reactive power automatic compensation controller
Jkwf series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement / sub supplement / CO supplement + sub supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 12 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: A: 0.86kg B: 0.78kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm / 138 × 138mm
Application orientation: industrial customers
-
JKWE-21(A/B) Connect the composite switch Factory Directly Sales Black Intelligent Reactive Compensation Controller
Jkwe series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 70 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 1I + 2U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 21 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants
Weight: 1.14kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 138 × 138mm
Application orientation: industrial customers
-
JKWD-12(A/B) Connect the composite switch Multiple control mode LCD Intelligent reactive power compensation controller
Jkwd series
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 1I + 2U / AC sampling
Working power supply: 220 VAC, 50 Hz
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 12 (A / b)
Human machine interface: LCD
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: Yes
Terminal block: plug in type
Quadrant control: two quadrants / four quadrants
Weight: A: 0.78kg B: 0.72kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm / 138 × 138mm
Application orientation: industrial customers
-
JKWB1-12(A) LCD screen Connect the composite switch LCD Intelligent reactive power compensation controller
JKWB1-16
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement method: 1i-2u AC sampling
Working power supply: common for pre measurement
Protection: over voltage, under voltage, temperature control, harmonic
Control scheme: CO supplement
Control output mode: static (a) / dynamic (b)
Number of control capacitor circuits: 16 (A / b)
Human machine interface: LCD
Communication: RJ45 network interface / RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: screw fixation
Quadrant control: two quadrants
Weight: 0.56kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: public power grid
-
JKWA-12B series intelligent reactive power automatic compensation controller
JKWA-12B
technical data
environment condition
Altitude: ≤ 2500
Working temperature: – 20 ℃~ + 60 ℃
Storage temperature: – 25 ℃ ~ + 70 ℃
Measurement mode: 3I + 3U / AC sampling
Working power supply: shared with measurement
Protection: over voltage, under voltage and harmonic
Control scheme: CO supplement
Control output mode: dynamic (b)
Number of control capacitor: 12 (b)
Human machine interface: LED
Communication: RS-485
Measurement accuracy: ± 0.5%
Forced circulation: None
Terminal block: screw fixation
Quadrant control: two quadrants
Weight: 0.58kg
anti-interference:
Pulse column width (MS): 15
Peak voltage of pulse train: 2KV, 1kV
Pulse polarity: positive and negative
Application time (s): 30
Support background: no
Opening size: 113 × 113 mm
Application orientation: public power grid, JP cabinet
Number of control capacitor: 12 / 32 (A / b)